LMC-3A AL-Cover Busbar Trunking


Categories:

Bus duct series


 

General Introduction

LMC-3A AL s hell busbar channel is used in the system of3 phases,4 wires,3 phases 5wires,50-60Hz, with ratedcurrent 100-5000A power suppy and distributuion, as a schemeof low cost and high efficiency for industrial factories, hospitalstotes, highrise buildings and those environment with high- techto achieve good cost performance.

 

General Introduction

Smallsize,goodfiexibility

Close sandwich type of structure saves space, and has good performance of reducing voltage. E ach functional unitwhose anale and height can be chanaed, can be installed in interlaver, alonaside wall and other architecture.

 

Convenientandfast connection

1、 Cone insulation plate reinforces mechanical strength, the modularized shell guarantees pressure without sharp adge2、Big scale bowl type manganese steel washer guarantees contact face even pressure.

3、 Common 19 wrench can fix double heads single bolt with red indication, if the red indication fall off, we can judge thatthe connection joint is fixed without any other testing tols.

4、Bolts can be reused during maintenance.

5、The joint has adjustable place of ± 16mm.

 

Full Al shell

1、 The shell is full close Al which is light and modularized, the special structure is fit for any installation place withoutthinking of any coefficient of reducing capacitance.

2、Sprayed full Al shell withstand 1000 hours of salt mist test.

3、Full Al shell features dust-proof performances aood ventilation.and electric conduction

 

Good electric conduction and insulation

1、The busbar adopts good copper and aluminum coated with tin or silvery, so the coating features good protection of anti-corrosion.

2、The conductor is wrapped by B calss (130%) Mylinex, which is insulative.

3、Adopt environmental protection insulative material, which is ROH required SGS 6 items of physical tests and is UL certified.

 

Jackboxstructure

1、The knob of jack box is installed in box body neck or side place, clear indication of switch on/off is provided.

2、Interlock mechanism is provided for fault switch on or other activity of getting power without permission.

3、Jack box with special fuse tool to get fuse easily.

4 、Modularized cover prevent ginger contact conductor unconsciously5、Special contactor is provided for internal earthing and shell earthing.

 

Technical Parameter

Earthing bar resistance

Rated current (A)

Earthing bar resistance (10-⁶Ω/m)

Rated current (A)

Earthing bar resistance (10-⁶Ω/m)

Copper conductor

Al conductor

Copper conductor

Al conductor

100

368.3

404.7

1350

96.6

107.7

160

368.3

404.7

1600

82.8

90.8

200

368.3

404.7

2000

66.5

74.8

250

368.3

404.7

2300

54.6

66.6

400

248.0

306.8

2500

44.9

62.2

500

213.6

248.8

3150

34.5

40.2

630

213.6

210.3

3800

29.6

33.3

800

168.2

163.0

4000

27.9

31.1

1000

139.5

141.0

4500

22.5

/

1250

112.3

112.5

5000

20.5

/

Attention:70℃,D.C.resistance,50%internal earthing

 

Rated short circuit value

Copper conductor

Rated current (A)

Effective rated thermostable current value (kA)

Effective rated dynamicstable current value (kA)

250~1000

30

63

1000~1600

50

105

2000-3150

65

143

3150~5000

100

220

 

Al conductor

Rated current
(A)

Effective rated thermostable current value (kA)

Effective rated dynamicstable current value (kA)

100-250

10

17

400-800

30

63

1000-2500

50

105

3150~4000

80

175

 

 

Ambien ttemperature influence to installation

Busbar channel works in the environment less than 40℃,and it can works continuously with max temperature.

rise of less than 30K under its rated value,and it can work for not less than 2 hours under 120%overload.

lf busbar channel works continuously in environment of high temperature,its capacitance should be reduced,

that is to say,the rated value x proper coefficinet.

 

Ambient temperature (℃)

Coefficient

40

1.00

45

0.95

50

0.90

55

0.85

60

0.80

65

0.74

70

0.67

 

Resistance reactance,impedance, voltage drop

Copper conductor

Rated current
(A)

Resistance

Reactance

Impedance

Voltage drop (V/m)

cosφ Power factor

(10-⁶Ω/m)

0.6

0.7

0.8

0.9

1.0

250

184.1

44.8

189.5

0.063

0.070

0.075

0.080

0.080

400

124.0

35.3

128.9

0.071

0.078

0.083

0.088

0.086

630

106.8

32.1

111.5

0.098

0.107

0.114

0.120

0.117

800

84.1

27.4

88.5

1.100

0.109

0.116

0.120

0.117

1000

69.8

24.1

73.8

0.106

0.114

0.122

0.121

0.121

1250

56.2

20.7

59.9

0.109

0.117

0.124

0.129

0.122

1350

48.3

18.3

51.7

0.102

0.110

0.116

0.120

0.113

1600

41.4

16.6

44.6

0.106

0.113

0.119

0.123

0.115

2000

33.3

14.2

36.2

0.108

116

0.122

0.125

0.115

2300

27.3

12.3

29.9

0.104

0.111

0.116

0.119

0.109

2500

22.4

10.7

24.9

0.096

0.101

0.106

0.108

0.097

3150

19.1

9.5

21.3

0.104

0.110

0.114

0.116

0.104

3800

14.8

6.5

16.2

0.093

0.099

0.104

0.106

0.098

4000

13.9

6.3

15.3

0.093

0.099

0.103

0.106

0.097

4500

11.2

5.4

12.5

0.086

91

0.095

0.097

0.088

5000

10.2

5.0

11.4

0.088

0.093

0.097

0.099

0.089

 

Al conductor

 

Rated current
(A)

Resistance

Reactance

Impedance

Voltage drop (V/m)

cosφ Power factor

(10-⁶Ω/m)

0.6

0.7

0.8

0.9

1.0

100

202.4

35.3

205.4

0.026

0.029

0.032

0.034

0.035

160

202.4

35.3

205.4

0.041

0.046

0.051

0.055

0.056

200

202.4

35.3

205.4

0.052

0.058

0.063

0.068

0.070

250

202.4

35.3

205.4

0.065

0.072

0.079

0.086

0.088

400

153.4

29.5

156.2

0.080

0.089

0.097

0.105

0.106

500

124.4

25.6

127.0

0.082

0.091

0.100

0.107

0.108

630

105.2

22.8

107.6

0.089

0.098

0.107

0.114

0.115

800

81.5

19.1

85.7

0.089

0.098

0.106

0.113

0.113

1000

70.5

17.1

72.6

0.097

0.107

0.116

0.123

0.122

1250

56.2

14.5

58.1

0.098

0.108

0.116

0.123

0.122

1350

50.6

13.6

52.6

0.097

0.106

0.114

0.121

0.119

1600

45.4

12.5

47.1

0.103

0.113

121

0.128

0.126

200O

37.4

10.9

38.9

0.108

0.118

0.126

0.133

0.130

2300

33.3

10.0

34.8

111

0.121

0.130

0.137

0.133

2500

31.1

9.5

32.5

0.114

0.124

0.132

0.139

0.135

3150

20.1

5.8

20.9

0.091

0.099

0.107

0.112

0.110

3800

16.7

5.0

17.4

0.092

0.100

0.108

0.113

0.110

4000

15.6

4.8

16.3

0.091

0.099

0.106

0.112

0.108

 

Size and Weight

 

Copper conductor

 

Current
(A)

Width
(mm)

Height
(mm)

Weight

Four lines (kg/m)

Five lines (kg/m)

250

128

77

9.0

9.5

400

128

87

11.5

12.3

630

128

92

12.5

13.4

800

128

102

15.0

16.2

1000

128

112

16.9

18.4

1250

128

127

20.9

22.7

1350

128

142

23.9

26.2

1600

128

157

27.7

30.4

2000

128

187

34.7

38.1

2300

128

222

42.7

47.1

2500

128

262

51.8

52.3

3150

128

339

62.6

69.3

3800

128

389

74.5

825

4000

128

409

79.3

87.9

4500

128

499

99.9

110.8

5000

128

539

109.6

121.6

 

Al conductor

 

Current
(A)

Width
(mm)

Height
(mm)

Weight

Four lines (kg/m)

Five lines (kg/m)

100-250

128

87

6.7

7.0

400

128

97

7.7

8.1

50

128

107

8.3

8.7

630

128

117

9.0

9.5

800

128

137

10.7

11.3

1000

128

152

11.5

12.2

1250

128

182

14.5

15.2

1350

128

197

15.0

16.2

1600

128

217

16.9

18.3

2000

128

257

20.1

21.7

2300

128

287

22.6

24.5

2500

128

307

24.5

26.6

3150

128

459

33.6

36.7

3800

128

549

40.7

44.5

4000

128

589

44.0

48.1

 